Sale!

500 LPH RO Plant

175,000.00 95,000.00

500 LPH RO plant

Working hour per day: 8 to 10 Hour

Out Put water per day:3000 Ltr 50 4000 Ltr

 

Description

Basic of Design and Capacity

Object: To commission a Reverse Osmosis System to recover 200 liters water per hour.

  1. Assumption:
    1. of working days :     360 days
    2. of working hours:     10 hrs
    3. Capacity utilization :     95-98%
  2. INPUTS (Waste Water Quality): Total Dissolved Solids: < 1500 PPM
  3. OUTPUT (Treated Water Quality): Total Dissolved Solids: <60-80 PPM

 

Technical Specifications:

Flow Rate:

  1. Feed Water: 500 LPH
  2. Treated Water: 250 LPH
  3. Rejected Water: 250 LPH
  4. Raw Water Pump:

Purpose:  To feed the dual media filter at pressure more than 2.0 bars, which is min. operating pressure for filter.

Specifications:

MOC: CI

  1. Type: Horizontal Centrifugal
  2. Flow Rate: 1200 liters per hour
  3. Head: 35m
  4. Power Required: 0.74kW
  5. Electrical: 220V, Single/Three phase, 50 HZ
  6. Cycle: 2900 rpm
  7. Make: CRI
  8. Quantity: 1 No.
  9. Dual Media Filter :

Purpose: To remove the total suspended solids, dirt, iron, and reduce silt density Index, total color, smell and odor which can foul the membranes.

Specifications: 

Vessel:

  1. Make: Pentair / Aventura
  2. Material of Construction: FRP
  3. Diameter: 250 mm
  4. Height: 1350 mm
  5. Testing Pressure: 10 kg/cm2
  6. Opening: Top
  7. Quantity: 1No.

 

Valve: 

  1. Make: UKL / Equivalent
  2. Material of Construction: Noryl
  3. Multiport Single Liver Valve
  4. Size : 1 inch
  5. Maximum Flow Rate: 12000LPH
  6. Working Pressure: 2-4 Bar
  7. Working : Down Flow

Media:

Mixed bed sand media consisting of the following

  1. i) Gravel ii) Pebbles iii) Quartz sand
  2. Average Porosity 50 micron particulate size
  3. Bed depth: 600mm
  4. Pipeline & Accessories:
  5. Pipe of PVC 10 bar tested pressure
  6. Dosing System:

Purpose: To dose antiscalant chemical to protect the scaling formation on RO Membranes.

Specifications:

MOC: PP

  1. Capacity: 6 LPH
  2. Pressure: 7 bar
  3. Qty: 1No.
  4. Make: E-Dose / Equivalent
  5. Micron Filter

Purpose: To remove the fine particles up to 05 microns and reduce silt density Index levels to acceptable level.

Specifications:

Cartridge Filter & Housing

Housing:

Make: L’eaupure

MOC of Housing: PP

  1. Length: 20”
  2. Diameter: 5.5”
  3. Quantity: 1No.

Cartridge:

Make: L’eaupure 

  1. Cartridge MOC: Polypropylene
  2. Length: 20”
  3. Diameter: 2.5”
  4. Quantity: 1No.
  5. Micron Rating: 05 micron
  6. High Pressure Pump

Purpose: To feed the Reverse Osmosis Membrane at pressure more than the osmotic pressure taking into consideration flux rate, flow and recovery.

Specifications:

MOC: Stainless Steel

  1. Type: Vertical Multistage
  2. Flow Rate: 1000 liters per hour
  3. Head: 135mwc
  4. Power Required: 1.5 kW
  5. Electrical: 440V, three phases, 50HZ
  6. Cycle: 2900rpm
  7. Make: CRI/ Shakti/ Equivalent
  8. Quantity: 1 No
  9. RO Membrane

Purpose: To remove the major part of TDS unto 98% by Reverse Osmosis Membranes arranged and designed to give adequate flow and Recovery.

Specifications:

  1. Type: Spiral Wounded
  2. Diameter of Membrane: 4.0 inch
  3. Length of Membrane: 1 mt.
  4. of Membranes: 1
  5. Recovery per Membrane: 10-15%
  6. Salt Rejection per Membrane: 98-99%
  7. Make of Membrane: Pentair CSM/ Equivalent
  8. System Recovery: 50%
  9. RO Pressure Tube

Purpose: To pack Reverse Osmosis Membranes and operate at high pressure Up to 300 psi.

Specifications:

MOC: FRP

  1. Diameter of pressure Vessel: 4.5 inch
  2. Length of Pressure Vessel: 2.2 m
  3. of Pressure vessel: 1
  4. of Membrane per vessel: 1
  5. Make: Flowtec / Equivalent
  6. Position: Horizontal, Series
  7. Arrays: 1 No.

 

 

 

 

 

  1. Electrical Panel

Purpose: Control panel is provided as a safety measure for the pump & other electrical items.

Specifications:

  1. Complete Starters overload relays.
  2. Voltmeter, Ammeter, MCB’s, Indicating lights
  3. Push Buttons
  4. Rocker switches for dosers
  5. Incommers, Auto-manual switches
  6. Instrumentation

Purpose

  1. Flow Meter: To measure the online flow of water
  2. TDS Meter: To measure the online TDS of water
  3. Low Pressure switch: To protect RO pump from dry running

Specifications:

Rota Meter:

  1. Quantity : 2 Nos. (Permeate & reject line)
  2. Range: 1.0 cu.m. Per hour
  3. Make: Flowtec / Equivalent
  4. Pressure Switch:
  5. Quantity : 2 No. (Low & High)
  6. Range: 0-450 psi
  7. Make: Flowtec / Equivalent
  8. Pressure Gauges:
  9. Quantity : 2No.
  10. Range: 0-7 Bar
  11. Dial size : 6 inches
  12. Type: Bourdon
  13. Make: Flowtec / Equivalent
  14. Plumbing & Fittings
  15. Complete, pipeline in UPVC to permeate line termination Point
  16. NRV’s, Pressure relief valves wherever needed
  17. The system will be on common MS base frame
  18. RO CLEANSING SYSTEM

Purpose:We provide a flushing system, which shall help to clean the Membrane and get rid of the floulants that get deposited on the Membranes.

Specifications:

  1. Flushing Time: 15 minutes
  2. Flushing Media: Treated Water/ Chemical
  3. Flushing Tank Size: 100L
  4. Tank MOC: HDPE
  5. Flushing pump: SS PUMP
  6. Semi automatic with two ball valves operation

 TERMS & CONDITIONS:

  1. Warranty: One Year Warranty
  2. Freight: Extra at actual
  3. Installation Charges: Free
  4. GST Tax: Taxes are extra as applicable
  5. Payment Terms: 50% Advance and 50% before Delivery Payment.
  6. Packaging: Extra

Installation and After sales service charge extra